DC/DC Converter
THD 10WIN Series, 10 Watt
•
•
UItra wide 4:1 input voltage range
•
•
High efficiency up to 87%
•
•
•
I/O isolation 1’500 VDC
Internal EMI-filter meets EN 55032,
Class A without external components
Operating temperature range
–40°C to +85°C
UL 62368-1 IEC 62368-1
The THD 10WIN series is designed for an optimized cost/performance ratio of
DC/DC converters with output power of 10 Watt. They come with an internal
EMI-filter to meet EN 55032, class A without external components. General
features like no minimum load requirement, overload protection and high efficiency make these converters easy to design in. With the popular DIP-24 standard package they are also a drop in replacement for many cost critical applications.
Overload protection
3-year product warranty
Models
Order Code
Input Voltage
Range
THD 10-2410WIN
THD 10-2411WIN
THD 10-2412WIN
THD 10-2413WIN
THD 10-2415WIN
THD 10-2422WIN
THD 10-2423WIN
THD 10-4810WIN
THD 10-4811WIN
THD 10-4812WIN
THD 10-4813WIN
THD 10-4815WIN
THD 10-4822WIN
THD 10-4823WIN
www.tracopower.com
9 - 36 VDC
(24 VDC nom.)
18 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5.1 VDC
12 VDC
15 VDC
24 VDC
+12 VDC
+15 VDC
3.3 VDC
5.1 VDC
12 VDC
15 VDC
24 VDC
+12 VDC
+15 VDC
2'700 mA
2'000 mA
833 mA
666 mA
416 mA
416 mA
333 mA
2'700 mA
2'000 mA
833 mA
666 mA
416 mA
416 mA
333 mA
September 20, 2023
Vnom
Efficiency
Imax
–12 VDC
–15 VDC
416 mA
333 mA
–12 VDC
–15 VDC
416 mA
333 mA
typ.
86 %
85 %
87 %
87 %
87 %
87 %
87 %
86 %
85 %
87 %
87 %
87 %
87 %
87 %
Page 1 / 4
THD 10WIN Series, 10 Watt
Input Specifications
Input Current
- At no load
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
- At full load
Surge Voltage
Start-up Voltage
Under Voltage Lockout
Reflected Ripple Current
Recommended Input Fuse
Input Filter
30 mA typ.
20 mA typ.
470 mA typ.
240 mA typ.
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
7 VDC min. / 8 VDC typ. / 9 VDC max.
14 VDC min. / 16 VDC typ. / 18 VDC max.
8.5 VDC max.
17 VDC max.
40 mAp-p typ.
30 mAp-p typ.
2'000 mA (slow blow)
1'000 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
Capacitive Load
- Voltage Balance
(symmetrical load)
- 20 MHz Bandwidth
- single output
3.3 Vout models:
5.1 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
- dual output
Minimum Load
Temperature Coefficient
Short Circuit Protection
Output Current Limitation
Transient Response
±2% max.
1% max.
1% max.
1.2% max.
1.2% max. (Output 1)
1.2% max. (Output 2)
dual output models: 2% max.
single output models:
dual output models:
single output models:
dual output models:
- Response Deviation
- Response Time
100 mVp-p max.
1'000 µF max.
1'000 µF max.
470 µF max.
330 µF max.
150 µF max.
220 / 220 µF max.
150 / 150 µF max.
Not required
±0.02 %/K max.
Continuous, Automatic recovery
150% typ. of Iout max.
3% typ. / 5% max. (75% to 100% Load Step)
300 µs typ. / 600 µs max. (75% to 100% Load
Step)
Safety Specifications
Safety Standards
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
CSA-C22.2, No. 60950-1
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/thd10win
PD 2
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 4
THD 10WIN Series, 10 Watt
EMC Specifications
EMI Emissions
EMS Immunity
- Conducted Emissions
- Electrostatic Discharge
- RF Electromagnetic Field
- EFT (Burst) / Surge
- Conducted RF Disturbances
EN 55032 class A (internal filter)
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
Air: EN 61000-4-2, ±8 kV, perf. criteria A
Contact: EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
Ext. input component: 220 μF, 100 V
EN 61000-4-6, 10 Vrms, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
Cooling System
Remote Control
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
- Input to Output, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
95% max. (non condensing)
–40°C to +85°C
+105°C max.
–50°C to +125°C
2.86 %/K above 70°C
See application note: www.tracopower.com/overview/thd10win
Natural convection (20 LFM)
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
10 mA max.
-0.5 to 0.5 mA
6'000 m max.
300 - 360 kHz (PWM)
330 kHz typ. (PWM)
Functional Insulation
1'500 VDC
1'000 MΩ min.
1'000 pF typ.
1'500 pF max.
1'000'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
Metal
Non-conductive Plastic (UL 94 V-0 rated)
Silicone (UL 94 V-0 rated)
Copper Alloy (C6801)
Nickel (2.5 µm min.)
Gold (75 - 125 nm), glossy
Metal Case
PCB Mount
THD (Through-Hole Device)
DIP24
Lead-Free Wave Soldering
260°C / 10 s max.
17.3 g
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 4
THD 10WIN Series, 10 Watt
Environmental Compliance - REACH Declaration
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
b791aa3f-0104-4139-9ff5-537e1ec921bd
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/thd10win
Outline Dimensions
9
11
Pinout
22
16
14
2.54 2.54
15.24 (0.600)
(0.100)(0.100)
4.1
5.08
4.5
(0.200)
(0.18)
Single
Dual
1
Remote On/Off
Remote On/Off
2
–Vin (GND)
–Vin (GND)
3
–Vin (GND)
–Vin (GND)
9
No pin
Common
–Vout
11
NC
14
+Vout
+Vout
16
–Vout
Common
22
+Vin (Vcc)
+Vin (Vcc)
23
+Vin (Vcc)
+Vin (Vcc)
(0.16)
Ø0.5 (Ø0.02)
Pin
NC: Not connected
10.2 (0.40)
23
2.54
Bottom View
20.3 (0.80)
3
15.22 (0.599)
2
(0.100)
1
31.8 (1.25)
Dimensions in mm (inch)
Tolerances: x.x ±0.50 (x.xx ±0.02)
Tolerances: x.xx ±0.25 (x.xxx ±0.01)
Pin diameter tolerance: x.x ±0.05 (x.xx ±0.002)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 4 / 4
很抱歉,暂时无法提供与“THD 10-2411WIN”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+223.57517
- 3+217.99592
- 5+214.63419
- 国内价格 香港价格
- 1+256.252001+30.63300
- 10+240.4739010+28.74690
- 20+232.5790020+27.80310
- 100+214.78330100+25.67580
- 200+213.76880200+25.55450
- 500+189.50100500+22.65340
- 国内价格
- 1+228.86365
- 2+216.61015
- 国内价格
- 1+2192.17075
- 2+2143.92185
- 4+2097.89048